Calculation Of Evaporation Loss in Tank Y and Tank Z at SA Field PT X Prabumulih

Sefilra Andalucia (1)
(1) a:1:{s:5:"en_US";s:29:"Politeknik Akamigas Palembang";}, Indonesia

Abstract

One of the facilities that plays an important role in the petroleum industry both in the fields of upstream oil and gas, downstream oil and gas, shipping and commerce is fluid storage area which is better known as a storage tank. Storage tank is very influential on the petroleum production process. Storage has an important role to accommodate and store fluid in the process of fluid distribution or fluid delivery from the production collector to the next destination such as production collection centers, refineries, and shipping. The storage tank used in SA Field is a fixed tap type tank (fixed roof tank). Fixed roof tanks are the most common type of tank among all tank cylinder and have a fixed conical roof with / without roof structure. Oil in storage tanks can experience losses. Losses are the disappearance or shrinkage of petroleum. Losses in this tank are caused by evaporation loss which is influenced by the temperature of the petroleum as well as the temperature from the weather outside the tank and the amount of free space in the tank. If the larger the free space in the tank, the greater the potential for evaporation of crude oil in the tank. In this study, an analysis of the factors causing evaporation loss will be carried out, calculation of evaporation loss, and calculation of the number of financial losses caused by evaporation loss in Tank X and Tank Y. Briefly, this research will be useful as one of the important references for the industry to find out the number of financial losses caused by evaporation loss.

Full text article

Generated from XML file

References

Arnold, K., & Stewart, M. (2007). Surface production operations, volume 1: Design of oil handling systems and facilities. In Surface Production Operations, Volume 1: Design of Oil Handling Systems and Facilities (3rd ed., Vol. 1). Elsevier. https://doi.org/10.1016/B978-0-7506-7853-7.X5001-7

Burhanuddin, B., Alfurkaniati, A., & Agustin, H. (2020). Studi Kelayakan Pendiri Badan Usaha Milik Daerah (BUMD) Migas Kabupaten Bengkalis. Pekanbaru: UIR Press. Retrieved from https://repository.uir.ac.id/14199/

Fajar, H. P. (2019). PENANGANAN PEMBONGKARAN GAS LPG TERHADAP PRESSURE DAN TEMPERATURE DARI KAPAL MT NAVIGATOR ARIES KE STORAGE OPERATION OLEH PT. MISI MULIA PETRONUSA CAB.BANYUWANGI. Semarang.

Kaiser, M. J., & McAllister, E. W. (2023). Tanks. In Pipeline Rules of Thumb Handbook (pp. 819–938). Elsevier. https://doi.org/10.1016/B978-0-12-822788-6.00016-5

Lichti, N. I., Steele, M. A., & Swihart, R. K. (2017). Seed fate and decision-making processes in scatter-hoarding rodents. Biological Reviews, 92(1), 474–504. https://doi.org/10.1111/BRV.12240

Makruf, A., Rahmadhani, R., Ningsih, S., Jayaditama, W., Rani, N., Sambaliung, A. J., … Samarinda -Indonesia, K. (2020). Pengukuran Tegangan, Arus, Daya pada Prototype PLTS Berbasis Mikrokontroller Arduin Uno. SainETIn : Jurnal Sains, Energi, Teknologi, Dan Industri, 5(1), 8–16. https://doi.org/10.31849/SAINETIN.V5I1.4370

McRae, J. A., Van Ness, K., & Khandekar, C. (2023). Crude oil storage. In Surface Process, Transportation, and Storage (pp. 299–323). Elsevier. https://doi.org/10.1016/B978-0-12-823891-2.00008-9

Setiorini, I. A., Faputri, A. F., Studi, P., Pengolahan, T., Politeknik, M., Palembang, A., & Corresponding Author, I. (2021). P PENYUSUTAN KARENA PENGUAPAN (EVAPORATION LOSS) PADA TANKI JENIS FLOATING ROOF TANK. Jurnal Teknik Patra Akademika, 12(01), 33–38. https://doi.org/10.52506/JTPA.V12I01.124

Stewart, M. (2021). Above ground storage tanks. In Surface Production Operations (pp. 677–776). Elsevier. https://doi.org/10.1016/B978-0-12-803722-5.00013-6

Varec, Chilingarian, G. V., & Kumar, S. (1987). Chapter 6 Vapor Recovery. Elsevier. https://doi.org/10.1016/S0376-7361(08)70535-1

Zai, B. S. (2021). Laporan Kerja Praktek di Pabrik Kelapa Sawit PT. Serdang Hulu Perkebunan Kelapa Sawit Tanjung Gunung. Universitas Medan Area. Retrieved from Universitas Medan Area website: https://repositori.uma.ac.id/handle/123456789/15116

Authors

Sefilra Andalucia
andalucia@pap.ac.id (Primary Contact)
Andalucia, S. (2023). Calculation Of Evaporation Loss in Tank Y and Tank Z at SA Field PT X Prabumulih. Journal of Earth Energy Engineering, 12(1), 19–27. https://doi.org/10.25299/jeee.2023.11934

Article Details

Received 2023-01-19
Accepted 2023-03-28
Published 2023-03-31