OPTIMIZATION OF Zn2+ METAL ION DETECTION USING PENCIL LEAD ELECTRODE MODIFIED WITH SILVER THIN LAYER BY CYCLIC VOLTAMMETRY METHOD
Keywords:
ion logam Zn2+, pencil lead electrode, silver thin layer, cyclic voltammetryAbstract
Zn2+ metal ions are heavy metals that are essential for the growth and development of organisms but if the amount of zinc (Zn) in excess can be toxic and disrupt the balance of the ecosystem. This research aims to study the electrochemical response of Ag/PLE to detect Zn2+ metal ions and determine the optimum conditions of supporting electrolyte and supporting electrolyte pH for the measurement of Zn2+ metal ions. In this study, electrochemical method was used to detect Zn2+ metal ion. The electrode was modified with a thin layer of silver by electrodeposition with the cyclic voltammetry method. The results showed that Ag/PLE gave a better response than PLE in detecting Zn2+ metal ions with acetate buffer solution with pH 4 as supporting electrolyte and optimum pH.
Downloads
References
Afifah, R., & Sari, T. K. (2024). Pengaruh Supporting Electrolyte Terhadap Deteksi Ion Logam Pb2+ Menggunakan Pencil Lead Electrode Termodifikasi Lapisan Tipis Perak dengan Metode …. Jurnal Pendidikan Tambusai, 8, 17970–17976. https://jptam.org/index.php/jptam/article/view/14938%0Ahttps://jptam.org/index.php/jptam/article/download/14938/11406
Andriani, V. (2007). Skripsi Pengembangan Sensor Voltametri N 2 O Dengan Optimalisasi Polarisasi Elektroda Dan Konsentrasi Elektrolit Menggunakan Konsentrasi Elektrolit Menggunakan.
Annu, Sharma, S., Jain, R., & Raja, A. N. (2020). Review—Pencil Graphite Electrode: An Emerging Sensing Material. Journal of The Electrochemical Society, 167(3), 037501. https://doi.org/10.1149/2.0012003jes
Anugrah Putri, Y., Kumala Sari, T., Oktavia, B., & K. U. (2024). Pengaruh Supporting Electrolyte Pada Penentuan Formaldehida Secara Voltametri Siklik Menggunakan Pencil Lead Electrode (PLE) Modifikasi Lapisan Tipis Perak. Periodic, 13(1), 38. https://doi.org/10.24036/periodic.v13i1.124524
David, I. G., Popa, D. E., & Buleandra, M. (2017). Pencil graphite electrodes: A versatile tool in electroanalysis. Journal of Analytical Methods in Chemistry, 2017(Cv). https://doi.org/10.1155/2017/1905968
Elgrishi, N., Rountree, K. J., McCarthy, B. D., Rountree, E. S., Eisenhart, T. T., & Dempsey, J. L. (2018). A Practical Beginner’s Guide to Cyclic Voltammetry. Journal of Chemical Education, 95(2), 197–206. https://doi.org/10.1021/acs.jchemed.7b00361
Fontana, M., & Greene, N. (1987). Mars Fontana-Corrosion Engineering(www.iranidata.com).pdf (p. nationalll).
Guimar, B., Saldanha, A., Teixeira, G. F., Colmati, F., Souza, A. R. De, Yves, I., Mac, L. De, Duarte, L. M., Oliveira, S. B. De, Carmo, G., Somerset, V. S., & Gil, E. D. S. (2023). Bismuth Vanadate-Nanostructured Graphite Electrodes for Rhodamine B Photoelectrochemical Degradation. 38–58.
Kalangie, D. J. M., Widowati, I., & Suprijanto, J. (2018). Kandungan Seng (Zn) dalam Air , Sedimen dan Kerang Darah (Anadara granosa L) di Perairan Tambaklorok Semarang. Journal of Marine Research, 7(1), 49–58. https://ejournal3.undip.ac.id/index.php/jmr%0A
Lestari, W., Azis, Y., & Ningsih, I. S. R. (2013). Fitoremediasi Zn Dari Limbah Cair Pabrik Pengolahan Karet Dengan Pemanfaatan. Journal of Chemical Information and Modeling, 53(9), 1689–1699.
Maharani, I. K., Sari, T. K., Dewata, I., Warda Ningsih, S. K., & Yamesa Away, R. D. (2024). Deteksi Formaldehida Menggunakan Glassy Carbon Electrode (GCE) Modifikasi Lapisan Tipis Emas secara Voltametri Siklik. Periodic, 13(1), 43. https://doi.org/10.24036/periodic.v13i1.124526
Marzuki, N. I., Bakar, F. A., Salleh, A. B., Heng, L. Y., Yusof, N. A., & Siddiquee, S. (2012). Development of electrochemical biosensor for formaldehyde determination based on immobilized enzyme. International Journal of Electrochemical Science, 7(7), 6070–6081. https://doi.org/10.1016/s1452-3981(23)19462-4
Palisoc, S., Espique, E. M., Ribay, A. M., Sy, S., Tan, K. A., De Jesus, N., Noel, M., & Natividad, M. (2018). Silver/bismuth/Nafion modified pencil graphite electrode for trace heavy metal determination. International Journal of Electrochemical Science, 13(11), 10355–10367. https://doi.org/10.20964/2018.11.63
Pura, J. L., Salvo-Comino, C., García-Cabezón, C., & Rodríguez-Méndez, M. L. (2023). Concurrent study of the electrochemical response and the surface alterations of silver nanowire modified electrodes by means of EC-AFM. The role of electrode/nanomaterial interaction. Surfaces and Interfaces, 38(February). https://doi.org/10.1016/j.surfin.2023.102792
Rosyidah, N. F., & Rachmadiarti, F. (2023). Salvinia molesta sebagai Agen Fitoremediasi Logam Berat Zink ( Zn ) di Perairan Salvinia molesta as Zinc ( Zn ) Heavy Metal Phytoremediation Agents in the Water. LenteraBio, 12(Vol. 12 No. 3), 430–438.
Sari, T. K., Riga, R., Zubir, M., Info, A., Science, N., Negeri, U., Science, N., Negeri, U., & Voltammetry, C. (2021). Eksakta. 22(02), 145–153.
Vasanthi Sridharan, N., & Mandal, B. K. (2022). Simultaneous Quantitation of Lead and Cadmium on an EDTA-Reduced Graphene Oxide-Modified Glassy Carbon Electrode. ACS Omega, 7(49), 45469–45480. https://doi.org/10.1021/acsomega.2c06080